« Return to Thread: Can't control x10 from RemoteLinc but can from webpage

Can't control x10 from RemoteLinc but can from webpage

by Brock Palen-3 :: Rate this Message:

Reply to Author | View in Thread

  recently upgraded to my first insteon gear,  and am trying to  
control an x10 appliance module connected to a lamp using a RemoteLinc  
controller.

I should point out that I have been able to pare the remote with the  
plm and mh, and two light modules.

I can control the x10 module from the mh webpage, but not form the  
small code I wrote to control from the remotelinc.  Note I am trying  
to have mh control the device,

Here is what I see when I control (successfully) from the webpage:

06/28/09 12:51:21 AM [Insteon_PLM] x10 sending code: A2 as insteon  
msg: 02636e00
06/28/09 12:51:21 AM [Insteon_PLM] x10 sending code: AJ as insteon  
msg: 02636280
06/28/09 12:51:21 AM [Insteon_PLM] Command stack size: 1
06/28/09 12:51:22 AM [Insteon_PLM] Parsing serial data: 02636e0006
06/28/09 12:51:22 AM [Insteon_PLM] Parsing serial data: 0263628006

Here is what happens when I try to control it from the remoteLinc

06/28/09 12:52:04 AM [Insteon_PLM] Parsing serial data:  
02500a2c85000002c71100
06/28/09 12:52:04 AM [Insteon_Device] command:11; type:alllink; group:  
02
06/28/09 12:52:04 AM [Insteon_Device] found: on
06/28/09 12:52:04 AM [Insteon_PLM] Processing message for  
$silver_button_2
06/28/09 12:52:04 AM [Insteon_Device]  
$silver_button_2::set_receive(on, Insteon_Link=HASH(0xb5f39a0))
06/28/09 12:52:04 AM silver remote on
06/28/09 12:52:04 AM [X10] Toggling X10_Item object $living_room_light  
from off to on
06/28/09 12:52:04 AM [Insteon_PLM] x10 sending code: A2 as insteon  
msg: 02636e00
06/28/09 12:52:04 AM [Insteon_PLM] x10 sending code: AJ as insteon  
msg: 02636280
06/28/09 12:52:04 AM [Insteon_PLM] Command stack size: 1
06/28/09 12:52:04 AM [Insteon_PLM] Parsing serial data: 02636e0006
06/28/09 12:52:04 AM [Insteon_PLM] Parsing serial data: 0263628006
06/28/09 12:52:05 AM [Insteon_PLM] Parsing serial data:  
02500a2c850fd787431102
06/28/09 12:52:05 AM [Insteon_Device] command:11; type:cleanup; group:  
02
06/28/09 12:52:05 AM [Insteon_Device] found: on
06/28/09 12:52:05 AM [Insteon_PLM] Processing message for  
$silver_button_2


Note that the commands MH says it is sending are the same, but nothing  
happens to the light.  Is this just insteon commands overwhelming the  
network?    What is that extra Parsing serial data lines?

Thanks,  I searched but could not find a similar issue.


Brock Palen
brockp@...
www.mlds-networks.com
MLDS Owner Senior Tech.



------------------------------------------------------------------------------
________________________________________________________
To unsubscribe from this list, go to: http://sourceforge.net/mail/?group_id=1365

 « Return to Thread: Can't control x10 from RemoteLinc but can from webpage