http://www.freescale.com/files/microcontrollers/doc/app_note/AN2283.pdf"As seen at the beginning of the flowchart the REC and TEC of the MSCAN are
set to 0 out of reset."
-rob
venkateshwarlu kacham wrote:
>
>
> Hi All,
>
> We are using the MSCAN in MPC5200B for my project CAN communication.
> I am aborting the CAN message whenever there is a TX PASSIVE Error
> occurs. I
> am creating the PASSIVE error by keeping CAN connection open.
>
> My Question is:
>
> The TX error counter values are never reset to ZERO though I did the CAN
> initialization. Does MSCAN Error counter register values become ZERO after
> every reset?if yes please let me know the complete RESET procedure.
>
> Hence Error counters are not becoming ZERO CAN controller is
> marinating its
> state in PASSIVE only so further unable to get the passive error interrupt
> for the new message transmission by keeping the CAN connection open.
>
> Thanks for your time.
>
> Regards,
> Venky
>
> [Non-text portions of this message have been removed]
>
>