Really........ Argh. I know how you feel. At times like this, OSS
is the way to go.
John
--- On Wed, 7/1/09, Mike Harrison <
mike@...> wrote:
> From: Mike Harrison <
mike@...>
> Subject: Re: [PIC] ICD2 as programmer : Why isn't it releasing reset afterprogram?
> To: "Microcontroller discussion list - Public." <
piclist@...>
> Date: Wednesday, July 1, 2009, 2:02 AM
> On Tue, 30 Jun 2009 11:20:12 -0400,
> you wrote:
>
> >Bob Axtell wrote:
> >> Mike, go back to MPLAB v7.4.
> >>
> >> The ICDC2 has never worked correctly, for me, on
> any version after
> >> 7.4 or 7.6.
> >
> >Or even better, ditch the ICD2 and get a RealICE.
> Those flaky random
> >disconnects seem to be gone, and they're cheap enough.
>
> Just got a reply from the ticket I submitted on this - They
> admit they screwed up but can't be
> bothered to fix it until MPLAB 10 comes out next year.
> Pathetic response for what would be a trivially easy fix.
>
>
> "The change of operation is known, and a result of conflict
> between 'Release from Reset' and the
> 'Hold in Reset' buttons were not in the correct state when
> "run after successful program" was
> enabled. This limitation is documented in the MPLAB
> ICD2 help overview section.
>
> The conflict will be resolved when the new MPLAB IDE 10 is
> released next year."
>
> --
>