have not rewired yet. Is there a functioning USB connector, vs the
> Hi Alan,
> On 6/12/2012 12:51 AM, Alan Womack wrote:
>> I haven't done any scenes. But a thought would to maybe do a factory
>> reset on the controller (if you are still just setting things up) and
>> wipe it completely clean and then take another crack at the scenes.
> At this point, neither end is indicating corruption, state unknown,
> etc. and I can turn on and off the load as desired and MH sees what is
> happening. I think I can move forward.
>> I don't quite have my head around them with misterhouse and it might
>> be one of those areas they have some bugs yet,
> Bugs are ok, I just need to know the workaround...
>> So are you trying to set up one switch from misterhouse in a scene
>> with your plm and that's it right now?
> Nearly correct. This is the first step. The second is to have on of the
> other buttons (BCDEF) control (activate) the scene and reflect it's
> state. This is where the surrogate comes into play (I think).
>
> Lastly, I want to control the state of BCDEF led from MH and from a
> different BCDEF button.
>>
>> Send me your MHT and I will modify it with two of my devices and see
>> what happens.
> I think I included it in the first post. Here is the Insteon section.
>
> # INSTEON devices
>
> INSTEON_KEYPADLINC, 1C.8B.49:01, Test_light, All_Lights
> INSTEON_KEYPADLINC, 1C.8B.49:02, Test_KP_B2,
> buttons|All_Buttons
> INSTEON_KEYPADLINC, 1C.8B.49:03, Test_KP_B3,
> buttons|All_Buttons
> INSTEON_KEYPADLINC, 1C.8B.49:04, Test_KP_B4,
> buttons|All_Buttons
> INSTEON_KEYPADLINC, 1C.8B.49:05, Test_KP_B5,
> buttons|All_Buttons
> INSTEON_KEYPADLINC, 1C.8B.49:06, Test_KP_B6,
> buttons|All_Buttons
> INSTEON_KEYPADLINC, 1C.8B.49:07, Test_KP_B7,
> buttons|All_Buttons
> INSTEON_KEYPADLINC, 1C.8B.49:08, Test_KP_B8,
> buttons|All_Buttons
>
> INSTEON_ICONTROLLER, 10, test_scene, all_scenes
>
> INSTEON_ICONTROLLER, F0, surrogate_scene, hidden
>
> SCENE_MEMBER, Test_KP_B6, surrogate_scene, surrogate
> SCENE_MEMBER, Test_KP_B8, surrogate_scene, surrogate
>
>
> SCENE_MEMBER, Test_light, test_scene, 100%, 0.1s
> SCENE_MEMBER, Test_KP_B6, test_scene,
> SCENE_MEMBER, Test_KP_B8, test_scene,
>
> SCENE_MEMBER, Test_light, Test_KP_B8, 100%, 0.1s
>
> SCENE_MEMBER, Test_KP_B8, Test_light
>
> Note that I have not tested this on the 'clean' setup. I was hoping for
> confirmation or correction prior to another round of tests. Aslo, In
> the OP I think I had the code commented out intentionally.
>>
>>
>> The Ezflora seems to be treated like a light switch from the couple of
>> samples I have dug up. I need to start coding out a module, but still
>> installing the sprinklers and want to get the weather module running
>> so I know if it is going to rain or not. We have had a week of rain,
>> and I was getting a kick of the number of sprinklers running IN the
>> rain or in the last 2 days after the rain.
> I will try to drag you into/onto 1-wire... You are aware that there are
> soil moisture sensors that have been made that use 1-wire protocol? I
> know where I live, projections while often accurate to the degree
> stated, really don't tell us whether or not our 'spot' will get wet or
> how wet it will end up if it does. A well placed soil sensor on the
> other hand...
>
>> Alan
>>
>> ------------------------------------------------------------------------------
>> Live Security Virtual Conference
>> Exclusive live event will cover all the ways today's security and
>> threat landscape has changed and how IT managers can respond. Discussions
>> will include endpoint security, mobile security and the latest in malware
>> threats.
http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/>> ________________________________________________________
>> To unsubscribe from this list, go to:
http://sourceforge.net/mail/?group_id=1365> Thanks again for your input,
> Peter
>>
>
>
> ------------------------------------------------------------------------------
> Live Security Virtual Conference
> Exclusive live event will cover all the ways today's security and
> threat landscape has changed and how IT managers can respond. Discussions
> will include endpoint security, mobile security and the latest in malware
> threats.
http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/> ________________________________________________________
> To unsubscribe from this list, go to:
http://sourceforge.net/mail/?group_id=1365>
threat landscape has changed and how IT managers can respond. Discussions