Hi Polly,
just released version 3.0.1. It has now this feature (again?). I renamed
the property since "ommit" is a typo. Use
mvn -Dfornax.generator.omit.execution=true clean install
to skip workflow execution.
~Karsten
On 21.05.09 11:18, Karsten Thoms wrote:
> Hi Polly,
>
> you are right. I was so sure that this feature is there that I did not
> read the source correctly, should have seen that #-) I think this
> feature was there once (did not check that yet) and I could add it
> again. Seems that I should create a bug fix release soon.
>
http://fornax.itemis.de/jira/browse/TOM-24>
> ~Karsten
>
> On 20.05.09 16:30, polly.c.chang wrote:
>> Hi Karten,
>>
>> Thanks for the quick reply. I saw the variable for
>> "force.execution", but
>> what about for *omitting* execution? The web page says that variable is
>> "fornax.generator.ommit.execution". This "ommit" variable is the one
>> that I
>> didn't see.
>>
>> Thanks for creating the ticket about adding outlets!
>>
>> Thanks,
>> Polly
>>
>>
>>
>> Karsten Thoms wrote:
>>> Hi Polly!
>>>
>>> The
>>>
>>> "fornax.generator.force.execution"
>>>
>>> is still supported. I think you have just overseen it, I did not change
>>> something here.
>>> if ("true".equalsIgnoreCase(
>>> System.getProperty("fornax.generator.force.execution"))) {
>>> getLog().info("Forced workflow execution");
>>> File timeStampFile = getTimeStampFile();
>>> if (timeStampFile != null){
>>> timeStampFile.delete();
>>> }
>>> }
>>>
>>> Additional Outlets cannot be added at the moment. Created a ticket:
>>>
http://fornax.itemis.de/jira/browse/TOM-23>>>
>>> ~Karsten
>>>
>>> On 19.05.09 18:18, polly.c.chang wrote:
>>>> Hi,
>>>>
>>>> Thank you for creating the oaw-m2-plugin and updating it to work with
>>>> both
>>>> TMF and OAW! I have a couple of questions about configuring this
>>>> plugin:
>>>>
>>>> 1. On the oaw-m2-plugin wiki page, the documentation says that it
>>>> should
>>>> be
>>>> possible to "execute the generation phase without the execution of
>>>> the
>>>> generator":
>>>>
>>>>
http://fornax.itemis.de/confluence/display/fornax/Configuration+(TOM)#Configuration(TOM)-Omittingtheexecutionofthegenerator
>>>>
>>>>
>>>> Is this still supported? I don't see any mention of the
>>>> "fornax.generator.ommit.execution" system property in the source
>>>> code. I
>>>> only see the "fornax.generator.force.execution" property mentioned.
>>>>
>>>> 2. Also, is it possible to configure new outlets? Not modify
>>>> existing
>>>> ones. I would like to add new ones.
>>>>
>>>> Thanks!
>>>> --Polly
>>>>
[karsten_thoms.vcf]
begin:vcard
fn:Karsten Thoms
n:Thoms;Karsten
org:itemis AG
adr:;;Am Brambusch 22;Luenen;;44536;Germany
email;internet:karsten.thoms@...
title:Softwarearchitekt
tel;work:+49 231 9860 202
tel;fax:+49 231 9860 211
tel;cell:+49 151 17396721
url:http://www.itemis.de
version:2.1
end:vcard
------------------------------------------------------------------------------
Register Now for Creativity and Technology (CaT), June 3rd, NYC. CaT
is a gathering of tech-side developers & brand creativity professionals. Meet
the minds behind Google Creative Lab, Visual Complexity, Processing, &
iPhoneDevCamp asthey present alongside digital heavyweights like Barbarian
Group, R/GA, & Big Spaceship.
http://www.creativitycat.com _______________________________________________
Fornax-developer mailing list
Fornax-developer@...
https://lists.sourceforge.net/lists/listinfo/fornax-developer