On Thu, Sep 13, 2007 at 10:24:08AM -0400, Kris Deugau wrote:
> >How do I disable AWL?
>
> Not sure; check the docs for the version of SA you're using. It *has*
> changed more than once in the last year or so IIRC.
It's still the same "use_auto_whitelist 0", though it's recommended to just
not load the plugin if possible (which it isn't in this case).
> >My users_prefs file does not currently have a bayes_expiry_max_db_size
> >option in it. Do I simply add one, setting a smaller value?
>
> Yep.
I would recommended against this. 150k is a good running value, making it
lower will potentially limit the effectiveness of using Bayes. It's also
worth noting that the expire system has forced minimum value of 100k here.
> >There's nothing that I can do with bayes_toks?
>
> To actually trim the file, you may have to discard the Bayes database
> you've got and train a new one with the new bayes_expiry_max_db_size
> value. BerkelyDB doesn't shrink the file when a record is deleted; you
> usually have to copy the live data to a new file and move it over top of
> the old one.
FWIW, that's exactly what the bayes expiry system does.
--
Randomly Selected Tagline:
"Phenomenal Cosmic Powers, Itty Little Living Space." - Aladdin